Salinity/temp sensor digital auto ranging
The EC1600 is a non-contact, toroidal electrical conductivity sensor that measures salinity and temperature over a wide range with high accuracy, without the corrosion or drift issues of contact-type sensors.
- Range
- 0-100,000 µS/cm ±2%
- Output
- SDI-12 and 4-20mA standard; RS232 on 12-pin variant
- Supply
- 10-18 V DC, <80 mA

Overview
In detail
How it works
The EC1600 uses a non-contact toroidal sensing element, avoiding the reliability and accuracy drift that affects contact-type EC sensors. Internal auto-ranging is transparent to the user, delivering a smoothly varying output up to 100,000 µS/cm while maintaining high resolution and accuracy across the full range - down to within a few percent of reading at 200 µS/cm and under 1% of reading from 1,000-100,000 µS/cm.
Extensive calibration mapping the sensor's response across many temperatures and salinity levels underpins this accuracy.
Connectivity
SDI-12 output is standard, supporting cable runs up to 250 m and all standard SDI-12 commands; a user-settable 4-20mA output is also standard, improving resolution when only a limited EC range is needed. A 12-pin variant adds an RS232 output. The EC1600 is backward compatible with the earlier EC1500 - cabling, connectors and installation fittings carry over unchanged.
What's included
Supplied with sealed cable as standard, or an optional waterproof connector (5-pin or 12-pin) with a matching calibrated torque wrench to prevent over- or under-tightening and maintain ingress protection.
Reach out and say hi
Specifications
Technical specifications
- Range
- 0-100,000 µS/cm ±2%
- Output
- SDI-12 and 4-20mA standard; RS232 on 12-pin variant
- Supply voltage
- 10-18 V DC, <80 mA
- Operating temperature
- 0-50°C (±0.2°C accuracy, 0-35°C)
- Sensor type
- Toroidal, non-contact EC sensor
- Measurement time
- <1 s (EC)
- Casing
- Delrin epoxy plastic
- Dimensions
- 295 x 49 x 20 mm (waterproof connector version)
Ready to specify?
Add Salinity/temp sensor digital auto ranging to your enquiry
Build a list, add your site notes, and an ESS engineer will quote the lot — cables, mounting and calibration included.